The workflow for restoration is as follows:

You usually start the machine as follows:

  1. Make sure that the machine is properly installed.
  2. Switch on the machine at the main power switch.
  3. If the machine controls the suction unit, switch on the unit and select the necessary extraction level.
    • The suction unit is not running. If it is, either the switching unit or the data cable of supported suction units is not properly installed.
  4. If you control the suction unit manually, you will switch it on immediately before job execution.

  5. Start the CAM computerClosed The computer that is connected to your machine and which runs DentalCAM and DentalCNC..
  6. Start DentalCNC.
    • The working chamber lighting lights up. The machine references.
  7. If the machine does not reference because the working chamber door is open, confirm the respective dialog on the CAM computerClosed The computer that is connected to your machine and which runs DentalCAM and DentalCNC.. Wait until the machine has referenced.

Starting the machine with a tool in the collet chuck

Under some circumstances like a power failure, there can be a tool in the collet chuck of the spindle when you start the machine.

NOTICE

Machine damage if you do not remove the tool

If the tool remains in the spindle after confirmation of the message, it will collide with and damage machine parts.

  • Remove the tool as described below.
  1. Start the machine.
    • DentalCNC displays that there is a tool in the collet chuck.
  2. Open the working chamber door.
  3. CAUTION!Wear gloves.

  4. Hold the tool in the collet chuck in place.

  5.  

  6. Confirm the current message.
    • The collet chuck opens.
  7. Remove the tool from the collet chuck.

     

  8. Confirm the current message.
    • The machine is ready for operation.

What's next?

Get to know the working chamber door and the multi-purpose compartment flap:

Operating the working chamber door and multi-purpose compartment flap

If you want to mount blanks:

Mounting and removing blanks

If you want to fill cooling liquid: