Applies to: E5

Starting the machine

The workflow for restoration is as follows:

Starting the machine

  1. Close the working chamber door.
  2. Switch on the machine at the main power switch.

  3. Start DentalCNC.

    • The working chamber lighting is on. The machine references.

 

Starting the machine with a tool in the collet chuck

Under some circumstances like a power failure, there can be a tool in the collet chuck of the spindle when you start the machine.

NOTICE

Machine damage if you do not remove the tool

If the tool remains in the spindle after confirmation of the message, it will collide with and damage machine parts.

  • Remove the tool as described below.

The following instructions require the tool in the collet chuck to be intact. If the tool is broken, remove it as described here: Removing broken tools from the collet chuck

  1. Start the machine.
    • DentalCNC displays that there is a tool in the collet chuck.
  2. Open the working chamber door.
  3. CAUTION!Wear gloves.

  4. Hold the tool in the collet chuck in place.

  5.  

  6. Confirm the current message.
    • The collet chuck opens.
  7. Remove the tool from the collet chuck.

     

  8. Confirm the current message.
    • The machine is ready for operation.