Applies to: DentalCAM & DentalCNC 8.10 / S2 / S5

Error code -1101 or 3101 – Error while loading the blank

This error code can occur while the machine is loading a blank from the blank magazineClosed Part of the blank changer in which you store the blanks for automatic loading. into the working chamber.

It indicates that the blank gripper could not reach its end position to mount the blank into the blank holder.

The corresponding end switch or sensor did not send a signal.

Interactive troubleshooting guide

Does the corresponding end switch or sensor now send a signal?

  1. Start DentalCNC.
  2. Open the DentalCNC Application settings. For this, select the following icon in the main icon bar
  3. Open the Machine maintenance view. For this, select the following icon in the lower icon bar
  4. Verify that the lower icon labeled 10 in the DG column is highlighted.

Icon which needs to be highlighted (marked orange)