Applies to: Z4

Technical data

Dimensions (W/D/H)

 

Unit

Value

Footprint (approx.)

mm

in

400 x 305

15.8 x 12.0

Housing fully closed (approx.)

 

mm

in

 

 

mm

in

Machine with internal CAM computerClosed The computer that is connected to your machine and which runs DentalCAM and DentalCNC.

471 x 522 x 507

18.5 x 20.6 x 20.0

 

Machine with external CAM computerClosed The computer that is connected to your machine and which runs DentalCAM and DentalCNC.

471 x 612 x 507

18.5 x 24.1 x 20.0

Minimum required space for operation (approx.)

 

mm

in

 

 

mm

in

Machine with internal CAM computerClosed The computer that is connected to your machine and which runs DentalCAM and DentalCNC.

620 x 620 x 650

24.4 x 24.4 x 25.6

 

Machine with external CAM computerClosed The computer that is connected to your machine and which runs DentalCAM and DentalCNC.

620 x 710 x 650

24.4 x 28 x 25.6

Base system

 

Unit

Value

Weight (approx.)

 

kg

lbs

 

 

kg

lbs

Machine with internal CAM computerClosed The computer that is connected to your machine and which runs DentalCAM and DentalCNC.

66

146

 

Machine with external CAM computerClosed The computer that is connected to your machine and which runs DentalCAM and DentalCNC.

67

148

Axes

– Rotational axis A / B

 

4

+190° to -10°

Integrated compressed air production

 

Protection class (IEC 60529)

 

IP20

Overvoltage category (IEC 60664-1)

 

II

Ambient conditions

 

Unit

Value

Relative humidity

 

80 %, non-condensing

Ambient temperature for storage/transport

°C

°F

‑2060

-4140

Ambient temperature for operation

°C

°F

1035

5095

Location type

 

Indoor

Maximum height above mean sea level

m

ft

2000

6561

Ambient air (IEC 60664-1)

 

Dust free, pollution degree 2

Electromagnetic radiation (IEC 61326-1)

 

Residential, business and commercial areas

Electromagnetic interference (IEC 61326-1)

 

Industrial environment

Spindle

 

Unit

Value

Model

 

SFZ 170P (asynchronous)

Maximum rotational speed

rpm

100,000

Nominal power under continuous operation (S1)

W

170

Nominal power under uninterrupted periodic operation (S6)

W

220

Peak power (Pmax)

W

340

Collet chuck diameter

mm

3

Tools

 

Unit

Value

Maximum number of tools in magazine

 

6

Maximum tool length

mm

35

Standard blank holder

 

Unit

Value

Maximum block dimensions (L/D/H)

mm

45 x 20 x 20

Cooling liquid system

 

Unit

Value

Cooling liquid

– For titanium

 

Drinking water

Emulsion of water and the cooling lubricant Tec Liquid Pro (optional)

Maximum amount of cooling liquid

l

qt

2

2.1

Sound emission

Operating condition

Unit

Value

Machining

– Sound pressure level

– Sound power level

 

dB(A)

dB(A)

 

81.8 dB(A)

92.3 dB(A)

All other operating conditions

dB(A)

<70 dB(A)

Measuring conditions

Value

Machined material

IPS e.max (block, C14)

Condition of the tools

new

Measured value

Sound pressure level (distance: 1 m)

Measurement according to

ISO 3746, accuracy grade 3

Connections

 

Unit

Value

Power connector

(and maximum power consumption in watts)

V AC

Hz

W

100 – 240

50/60

750

Glass fuse T6,3A L250V

Network connection

– Speed

 

RJ-45

10BASE/100BASE-TX/1000BASE-T (Auto-sensing)

With external CAM computerClosed The computer that is connected to your machine and which runs DentalCAM and DentalCNC. not on the machine.

External CAM computer

Variant 1

Value

Operating system

Windows 10 IoT Enterprise 2019

Processor

Intel® Core™ i5-9300H (4 x 2.4 to 4.1 GHz)

Random Access Memory

8 GB (2 x SO-DIMM DDR4 PC2400)

Hard drive

SSD M.2 NVMe 256GB PCIe3.0x4

Connections

4 x USB 2.0 A

1 x DisplayPort 1.2

3 x RJ-45 10BASE/100BASE-TX/1000BASE-T (Auto-sensing)

Electrical supply: input voltage 12 V DC

Variant 2

Value

Operating system

Windows 10 Pro / IoT

Processor

Intel® Core™ i5-9400T

Random Access Memory

8 GB (2 x SO-DIMM DDR4 PC2666)

Hard drive

SSD M.2 B-Key 2280 NVMe 256GB

Connections

2 x USB 2.0 A

2 x USB 3.1Gen 1

1 x DisplayPort 1.2

1 x HDMI 1.4

1 x RJ-4510BASE/100BASE-TX/1000BASE-T (Auto-sensing)

Electrical supply: input voltage 19 V DC

WiFi

Machines with internal CAM computerClosed The computer that is connected to your machine and which runs DentalCAM and DentalCNC.

 

Value

Standards

IEEE 802.11 ac

Data rate

802.11 ac: downlink up to 867 Mbps, uplink up to 867 Mbps (20/40 MHz)

802.11 a/b/g/n/ac: downlink up to 300 Mbps, uplink up to 300 Mbps (20/40 MHz)

Encryption

64-bit WEP

128-bit WEP

WPA2-PSK

WPA-PSK

Operating frequency

2.4 GHz / 5 GHz

Channels

2.4 GHz: 1~13 ch

5 GHz: Channels 36~64, channels 100~140

Machines with external CAM computerClosed The computer that is connected to your machine and which runs DentalCAM and DentalCNC.

Variant 1

Value

Standards

IEEE 802.11a, b, d, e, g, h, i, k, n, r, u, v, w, ac, ax

Data rate

802.11ax dual band 2x 2 160 MHz

Bluetooth®

Bluetooth® 5.2

Encryption

128-bit AES-CCMP

256-bit AES-GCMP

WPA2, WPA3

802.1X EAP-TLS, EAP-TTls/MSCHAPv2, PEAPv0-MSCHAPv2

Variant 2

Value

Standards

IEEE 802.11a, b, d, e, g, h, i, k, n, r, u, v, w, ac,

Data rate

802.11ac dual band 2x 2 160 MHz

Bluetooth®

Bluetooth® 5.1

Encryption

128-bit AES-CCMP

256-bit AES-GCMP

WPA2 / WPA3

802.1X EAP-TLS, TTLS, PEAP, EAP-SIM, EAP-AKA