Applies to: S5

Technical data

Dimensions (W/D/H)

 

Unit

Value

Footprint (approx.)

mm

in

599 x 266

23.6 x 10.5

Housing fully closed (approx.)

mm

in

700 x 444 x 561

27.6 x 17.5 x 22.1

Minimum required space for operation (approx.)

mm

in

1050 x 770 x 600

27.6 x 26.9 x 22.1

Base system

 

Unit

Value

Weight (approx.)

kg

lbs

106

234

Axes

– Rotational axis A

 

5

360° / ± 30°

Overvoltage category (IEC 60664-1)

 

II

External compressed air supply

 

Unit

Value

Min. / max. air pressure

bar

psi

6 / 8

90 / 120

Recommended air pressure

bar

psi

7

100

Compressed air consumption (approx.)

Wet machining

 

Dry machining

 

 

l/min

cfm

l/min

cfm

 

30/35 (at 6/8 bar)

1.1/1.2 cfm (at 90/120 psi)

60/73 (at 6/8 bar)

2.1/2.6 (at 90/120 psi)

Air purity (ISO 8573-1:2010)

 

Solid particles: class 3

Water: class 4

Total oil content: class 3

External air extraction system

 

Unit

Value

Minimum extraction capacity

l/min

cfm

3,000 (at 220 hPa)

105.9 (at 3.2 psi)

Suction unit

 

Designed for the commercial use in the dental sector

Equipped with a filter of the filter class M

Ambient conditions

 

Unit

Value

Relative humidity

 

80 %, non-condensing

Ambient temperature for storage/transport

°C

°F

‑2060

-4140

Ambient temperature for operation

°C

°F

1035

5095

Location type

 

Indoor

Maximum height above mean sea level

m

ft

2000

6561

Ambient air (IEC 60664-1)

 

Dust free, pollution degree 2

Electromagnetic radiation (IEC 61326-1)

 

Residential, business and commercial areas

Electromagnetic interference (IEC 61326-1)

 

Industrial environment

Spindle

 

Unit

Value

Model

 

SFS 300P (synchronous)

Maximum rotational speed

rpm

60,000

Nominal power under continuous operation (S1)

W

300

Nominal power under uninterrupted periodic operation (S6)

W

450

Peak power (Pmax)

W

600

Collet chuck diameter

mm

3

Tools

 

Unit

Value

Maximum number of tools in magazine

 

16

Maximum tool length

mm

40

Standard blank holder

 

Unit

Value

Min. / max. disc diameter

mm

98.3 / 98.7

Maximum disc height

mm

30

Min. / max. height of the disc rim

mm

10 / 10.5

Cooling liquid system

 

Unit

Value

Prepared for wet machining

 

Requires vhf wet grinding module

Blank changer

 

Unit

Value

Number of slots

 

8

Mounting method

 

Blank frames required (8 provided)

Sound emission

Operating condition

Unit

Value

Machining

dB(A)

77 dB(A)

All other operating conditions

dB(A)

<70 dB(A)

Measuring conditions

Value

Machined material

CoCr

Condition of the tools

worn

Measured value

Sound pressure level (distance: 1 m)

Measurement according to

ISO 3746, accuracy grade 3

Connections

 

Unit

Value

Pneumatic connection, push-in fitting (Diameter)

mm

6

Power connector

(and maximum power consumption in watts)

V AC

Hz

W

100 – 240

50/60

850, Glass fuse T6,3A L250V

USB port

 

2.0 A

Data port for supported suction unit or switching unit

 

Yes

Hose connection for external air extraction system (Diameter)

mm

45

Data port for wet grinding module

 

Yes

Hose connection for wet grinding module (Diameter)

mm

6

Pin assignment of the suction unit data port

80 %, non-condensing

  1. + 24 V, switched, output 1
  2. + 24 V, switched, output 2 (not used)
  3. +24 V, continuous
  4. Rear signal input, output 2 (not used)
  5. Rear signal input, output 1 (not used)
  6. Ground (PE)

DentalCAM system requirements