What is the intended use of the machine? When will I lose my entitlement to benefits?
In the event of a violation of the following regulations, your entitlement to benefits may be forfeited.
Machine damage if you violate these regulations
If you violate the following regulations, your machine may get damaged and / or cause damage in the surrounding area(s).
- Thoroughly follow all instructions and information in this section.
Intended use
The machine and the manufacturing software Term for the software package consisting of DentalCAM and DentalCNC. have been designed for the commercial machining of dental objects by specially trained persons. The processed objects require additional work before their use on patients.
- Only process materials that you can select in the manufacturing software Term for the software package consisting of DentalCAM and DentalCNC..
- Only use the machine in a commercial environment.
- Before creating jobs, verify if the objects being prepared may be utilized at the place of use according to local and / or national regulations or other authorized organizations or entities (e.g. professional associations, health authorities). In particular, check whether the material is approved in general and for the indication being manufactured in particular, and whether the respective indication is manufactured in accordance with the valid regulations. Neither the manufacturing software Term for the software package consisting of DentalCAM and DentalCNC. nor the machine will inform you about possible infringements but will execute jobs as you set them.
- For each indication and for each material, check whether you are authorized to manufacture the indication or use the material. Obtain authorization from the appropriate organization (e.g., professional associations, health authorities) as needed.
- Only import objects into the manufacturing software Term for the software package consisting of DentalCAM and DentalCNC. that correspond to the object types that you can select in the manufacturing software Term for the software package consisting of DentalCAM and DentalCNC.. While you can import / manufacture any other objects as well, neither the manufacturing software Term for the software package consisting of DentalCAM and DentalCNC. nor the machine are designed for these other objects.
- Do not manufacture implants or parts that touch implants. These parts include parts of two-part abutments which contain the connection geometry for the implant. Do not manipulate the connection geometry of prefabricated abutments (“prefab abutments”), and check whether the connection geometry has been damaged on the finished object.
Controlling the machine through software
You control the machine through specially designed applications which are supplied with the machine.
- Always use the latest version of the application that officially supports your machine.
- Before installing or operating the machine, read the documentation for the applications.
- Ensure that your CAM computer The computer that is connected to your machine and which runs DentalCAM and DentalCNC. meets all system requirements.
Maintenance and cleaning
- Clean and maintain the machine as required. Only then can the machine reach a long service life.
- Only perform maintenance tasks that are described in the operating instructions for the machine.
Spindle
The spindle of your machine is a high-precision instrument.
- Do not use any tools with high imbalance at high rotational speeds. Such an imbalance puts a great strain on the spindle’s ball bearings, which can damage the ball bearings.
- When working in the working chamber, do not apply manual pressure against the spindle.
Unattended operation
If the machine runs unattended, the risk of material damage is increased.
- Only allow unattended operation of the machine to occur if the following conditions are met:
- The national and local laws allow it.
- The working chamber of the machine is completely clean.
- Unauthorized users cannot access the machine.
- The room in which the machine is located has an automatic fire detection system.
Transportation and storage
Injuries caused by unsafe transportation
If you transport the machine unsafely, the machine may slip and cause injuries.
Parts that are not properly mounted can fall and injure you and/or become damaged.
-
Only stack machines that are properly packed and secured against slipping.
- Ensure that only trained personnel transport the machine to and from the installation site.
- Ensure that the machine housing is completely closed.
- Always transport the machine in an upright position.
- Transport and position the machine with as many people as required for the weight of the machine in accordance with local and / or national laws and regulations.
- Carry unpacked machines only with the carrying aid installed. Make sure that all components are secured. Do not use any other carrying aid.
- Grab unpacked machines only at the handles of the carrying aid. Always carry the machine in an upright position.
Machine damage due to improper transport and / or storage
-
Ensure that all conditions set forth in the chapter are met during the entire transport and / or storage period Technical data.
Short-circuit hazard when the machine is too cold
If the machine is transported from a cold environment into a warmer environment, a short circuit may occur caused by condensate.
- Before switching on the machine after transportation, ensure the following:
- The ambient air has the allowed temperature.
- The machine has the same temperature as the ambient air. This will take at least 48 hours.
- The machine is completely dry.
The supplement about the carrying aid and transport lock is delivered with the machine. They are also available for download here.
Preparing for transportation or storage
- Remove all blanks from the working chamber.
- Remove all items from the blank magazine Part of the blank changer in which you store the blanks for automatic loading..
- If the machine was used for wet machining:
- Rinse the cooling liquid system.
- Empty and clean the cooling liquid tank. Ensure that the tank is completely dry.
- Clean the working chamber. Ensure that the working chamber is completely dry.
- Clean the blank magazine Part of the blank changer in which you store the blanks for automatic loading..
- Install the transport lock. For this, follow the corresponding steps on the attachment.
- Ensure that the machine housing is completely closed.
- Switch off the machine via the main power switch.
- Disassemble the machine components by following the installation instructions in reverse order.
- If you need to carry the machine, install the carrying aid. For this, follow the corresponding steps on the supplement.
- In case of overseas transport, take proper measures against corrosion.
Packing the machine
To repack the machine after preparing its transportation or storage, the following steps are necessary:
-
If possible, use the original packaging. If the original packaging is not available, use a packaging of similar size and quality.
Original packaging is available from customer service.
- Pack the machine and its accessories securely. Follow the instructions on the supplement.
- Protect the packaging against slipping. If machines are properly packed and protected against slipping, they may be stacked.