Applies to: E5

Exchanging the measuring key protective cap

If the measuring key protective cap is torn or very soiled, exchange it.

Watch the video

YouTube video – When viewing this video, personal data is sent to YouTube, LLC, USA. Privacy statement

  1. Have ready:
    • 1 x Measuring key protective cap

    •  

    • 1 x Suction unit with category M filter

    •  

  2. CAUTION!Wear gloves.

  3. Remove the tool from position E1.

  4. Suck the machining residues from the measuring key.

  5.  

     

     

  6. Loosen the fixing ring by turning it by hand counter-clockwise. Pull the fixing ring up.

  7. Remove the measuring key protective cap by pulling upward.

  8.  

     

     

  9. Plug the replacement guard onto the measuring key pin.

    Make sure that the underside of the cap engages evenly at all points.

  10. Replace the fixing ring by manually turning it in the clockwise direction.

  11.