Release Notes
For a list of previous DentalCAM & DentalCNC 7 updates and release notes, see Release notes history (Version 7)
Version 7.09
New functions | Improvement of an existing function | Bug Fixes
Crushing hazard due to open blank magazine Part of the blank changer in which you store the blanks for automatic loading.
For details see (S5) Cleaning position can no longer be approached with the blank magazine door open.
- Update to DentalCAM & DentalCNC 7.09 immediately.
DentalCAM
(R5, S1, S2, S5) nt-trading Preform holder with unilateral mount is now supported
Previously, only the nt-trading Preform abutment holder with bilateral mount was supported. You can now also use the version with unilateral mount.
When updating, you must first activate new blank types. Customizing the blank type list
-
If you are using the unilateral mount, when creating a job from the Blank type drop-down list, select the nt-Trading unilateral -Ti entry.
If you are using the holder with bilateral mount, select nt-Trading bilateral -Ti.
You can activate and deactivate both versions separately:
Grooves on objects no longer occur
With some objects, grooves occurred on the objects due to connections between milling paths.
This behavior has been corrected.
DentalCNC
New firmware version for all supported machines except K4
For all supported machines except K4, DentalCNC contains the following firmware version: 10.86.61
This behavior has been corrected.
(S5) Cleaning position can no longer be approached with the blank magazine door open
When moving the axes to the cleaning position, users could reach into moving parts of the blank changer Machine component which stores multiple blanks in a magazine and which can automatically load them into the working chamber.. When using the search, use a blank changer or a blank magazine instead.
This behavior has been corrected.
(N4, N4+, Z4) Elimination of the need to enable CAD/CAM integration for individual CAD applications by code
Previously, CAD/CAM integration had to be enabled separately by code for the CAD application in use. You can now simply select the CAD/CAM integration and 3Shape Produce enabled option in the general application settings.
(Z4) Video recording now stops at the end of machining
The recording of the working chamber by the internal webcam for service purposes previously only stopped after you responded to the job deletion dialog. But this allowed the creation of very large video files.
This behavior has been corrected.
(Z4 with integrated workflow) Transfer of quality setting from exocad ChairsideCAD and TRIOS Design Studio to DentalCNC now works correctly
The machining quality selected in exocad ChairsideCAD or TRIOS Design Studio was machined incorrectly by DentalCNC. The objects were machined at a lower setting.
This behavior has been corrected.