Release Notes

For a list of previous DentalCAM & DentalCNC 7 updates and release notes, see Release notes history (Version 7)

Version 7.09

 New functions | Improvement of an existing function | Bug Fixes

DentalCAM

(R5, S1, S2, S5) nt-trading Preform holder with unilateral mount is now supported

Previously, only the nt-trading Preform abutment holder with bilateral mount was supported. You can now also use the version with unilateral mount.

When updating, you must first activate new blank types. Customizing the blank type list

  • If you are using the unilateral mount, when creating a job from the Blank type drop-down list, select the nt-Trading unilateral -Ti entry.

    If you are using the holder with bilateral mount, select nt-Trading bilateral -Ti.

You can activate and deactivate both versions separately:

Grooves on objects no longer occur

With some objects, grooves occurred on the objects due to connections between milling paths.

This behavior has been corrected.

DentalCNC

New firmware version for all supported machines except K4

For all supported machines except K4, DentalCNC contains the following firmware version: 10.86.61

This behavior has been corrected.

(S5) Cleaning position can no longer be approached with the blank magazine door open

When moving the axes to the cleaning position, users could reach into moving parts of the blank changerClosed Machine component which stores multiple blanks in a magazine and which can automatically load them into the working chamber.. When using the search, use a blank changer or a blank magazine instead.

This behavior has been corrected.

(N4, N4+, Z4) Elimination of the need to enable CAD/CAM integration for individual CAD applications by code

Previously, CAD/CAM integration had to be enabled separately by code for the CAD application in use. You can now simply select the CAD/CAM integration and 3Shape Produce enabled option in the general application settings.

(Z4) Video recording now stops at the end of machining

The recording of the working chamber by the internal webcam for service purposes previously only stopped after you responded to the job deletion dialog. But this allowed the creation of very large video files.

This behavior has been corrected.

(Z4 with integrated workflow) Transfer of quality setting from exocad ChairsideCAD and TRIOS Design Studio to DentalCNC now works correctly

The machining quality selected in exocad ChairsideCAD or TRIOS Design Studio was machined incorrectly by DentalCNC. The objects were machined at a lower setting.

This behavior has been corrected.